8.3 SMAW Electrodes

David Ridge

Electrode Classification

There are dozens of different SMAW electrodes on the market today. This is because of the wide variety of metals that need to be welded. In all welding applications that require a filler metal, it is important to match that filler metal with the base metal. This is because different metals do not always bond well to each other. Welds made with metals that are too dissimilar to each other are likely to fail. For example, you would want to weld a steel alloy base metal with a steel alloy filler metal, a stainless steel with a similar stainless steel, or a titanium alloy with titanium. You would not try to weld steel with titanium filler metal, as the two would not mix well. Even within these broad categories of metals, it is necessary to accommodate the many variations in the type of base metal alloy. For instance, a high-strength steel would need to be welded with a similar high-strength steel filler metal. Additionally, some elements in the flux make different electrodes suitable for some applications but not others, such as electrodes that keep a weld low in hydrogen, a major cause of weld failure, versus an electrode that can weld underwater, a major source of hydrogen.

With all that being said, it is very important to be able to identify the filler metal you are working with. Most metals cannot be easily identified just by looking at them. Therefore, it is necessary to have a quick and efficient means of electrode identification. To that end, the AWS has devised the filler metal classification system. This system is a simple code of letters and numbers that can be printed on the electrodes themselves or on their packaging (American Welding Society, 2012).

Several welding electrodes showing the printed electrode classifications. The electrode classifications are discussed in the text.
Figure 8.16. Different Electrodes / Photo Credit: Ghasemimoshref, CC BY-SA 4.0

With a quick glance, this system allows you to have the basic information needed in order to use the electrode properly. Each letter and number in the system has a meaning. This section discusses each component of this system in detail. Before we begin, it is worth mentioning that studying electrode classification involves some memorization. You want to focus on memorizing the order in which the system is read. As you will see, the order goes prefix, tensile strength, welding position, flux type/polarity requirements, and additional requirements (if any). Each character or group of characters in the classification corresponds to one of those items, and you will know which one by remembering the order. Keeping this in mind will help you pick up how to read a SMAW electrode classification more quickly.

It is important to note that the system covered here is for identifying SMAW electrodes for welding carbon steel. There are separate filler metal classification systems for each different type of filler metal/electrode for each welding process. Those will be discussed in their respective chapters.

Prefix

The basic filler metal classification system for carbon steel electrodes takes this form: the capital letter E followed by four to five numbers.

A SMAW electrode classification system diagram with each part labeled. E is for electrode, followed by two characters for tensile strength. The position, polarity, and flux composition is presented in the last two characters.
Figure 8.17. SMAW Electrode Classification / Photo Credit: © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator)

The letter at the beginning of the classification is called the “prefix.” The prefix tells you what form the filler metal takes. In the case of SMAW, the prefix will always be the letter E, which stands for electrode. For a filler metal to be classified as an electrode, the welding current must pass through it to complete the circuit. This is always true for the SMAW process. Not all welding processes use an electrode as a filler metal, so the prefixes for those classifications will differ.

Tensile Strength

Tensile strength is a measure of the force required to pull something apart. In the case of a weld, it is the force required to break the weld by pulling it apart and is measured in thousands of pounds per square inch (example: 70,000 psi or 70 ksi).

After the prefix, the next two to three numbers in the classification indicate the filler metal’s minimum tensile strength in the “as welded” condition (see image 8.17 above). For example, in the classification E6010, the 60 indicates that the minimum tensile strength for a weld made with this electrode is 60,000 psi. For a classification like E7018, the tensile strength would be 70,000 psi, and for E11018 it would be 110,000 psi.

A SMAW electrode classification system diagram with each part labeled. E is for electrode, followed by two characters for tensile strength here shown as “70” meaning the tensile strength would be 70,000 psi. The position, polarity, and flux composition is presented in the last two characters, one and eight.
Figure 8.18. Example of SMAW Electrode Classification / Photo Credit: © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator)
Table 8.1. Tensile Strength

Class

Min. Tensile Strength

Min. Yield Strength

E60xx

62,000 psi

50,000 psi

E70xx

70,000 psi

57,000 psi

E80xx

80,000 psi

67,000 psi

E90xx

90,000 psi

77,000 psi

E100xx

100,000 psi

87,000 psi

E110xx

110,000 psi

95,000 psi

E120xx

120,000 psi

107,000 psi

One thing to note is that this strength rating is designed to meet the minimum tensile strength required for the weld if welding is performed correctly. These electrodes can generally produce a weld with a tensile strength anywhere from 1% to 20% higher than they are rated for. Keep in mind that this is not an excuse for any welder, fabricator, or design engineer to exceed the rated tensile strength for a filler metal when designing or building a weldment or welded structure. It is generally better to have more strength in a weld than necessary.

Welding Position

A table showing the different welding positions for fillet welds on plate, groove welds on plate, and groove welds on pipe. Weld positions are discussed in the text below.
Figure 8.19. Fillet and Groove Welding Positions / Photo Credit: Nicholas Malara, CC BY 4.0

The single number after the tensile strength designator indicates the welding position(s) that this electrode can be used in (see image 8.18 above). Welding positions are discussed in greater detail in Chapter 15. The number 1 in this space indicates that the electrode can be used in all positions. The number 2 indicates that the electrode can only be used for welds in the flat position (1F, 1G) and for horizontal fillet welds (2F). The number 4 indicates that the electrode can be used in all positions, but when welding in the vertical position (3F, 3G) the weld progression must be down instead of up.

Table 8.2. Welding Position

Electrode Classification

Type of Flux Coating

Welding Position(s)

Type of Current

E6010

High cellulose sodium

Flat, Vertical, Overhead, Horizontal

DCEP

E6011

High cellulose potassium

Flat, Vertical, Overhead, Horizontal

AC, DCEP

E6012

High titania sodium

Flat, Vertical, Overhead, Horizontal

AC, DCEN

E6013

High titania potassium

Flat, Vertical, Overhead, Horizontal

AC, DCEP, DCEN

E6018

Low-hydrogen potassium, iron powder

Flat, Vertical, Overhead, Horizontal

AC, DCEP

E6019

Iron oxide titania potassium

Flat, Vertical, Overhead, Horizontal

AC, DCEP, DCEN

E6020

High iron oxide

Flat, Horizontal fillet

AC, DCEP, DCEN (Flat only)

E6022

High iron oxide

Flat, Horizontal fillet

AC, DCEN

E6027

High iron oxide, iron powder

Flat, Horizontal fillet

AC, DCEP, DCEN (Flat only)

E7014

Iron powder, titania

Flat, Vertical, Overhead, Horizontal

AC, DCEP, DCEN

E7015

Low-hydrogen sodium

Flat, Vertical, Overhead, Horizontal

DCEP

E7016

Low-hydrogen potassium

Flat, Vertical, Overhead, Horizontal

AC, DCEP

E7018

Low-hydrogen potassium, iron powder

Flat, Vertical, Overhead, Horizontal

AC, DCEP

E7018M

Low-hydrogen iron powder

Flat, Vertical, Overhead, Horizontal

DCEP

E7024

Iron powder, titania

Flat, Horizontal fillet

AC, DCEP, DCEN

E7027

High iron oxide, iron powder

Flat, Horizontal fillet

AC, DCEP, DCEN (Flat only)

E7028

Low-hydrogen potassium, iron powder

Flat, Horizontal fillet

AC, DCEP

E7048

Low-hydrogen potassium, iron powder

Flat, Overhead, Horizontal, Vertical down

AC, DCEP

You may have noticed that the number 3 was skipped. The AWS no longer uses the number 3 to indicate welding position, as the electrodes that had a 3 designation are now obsolete.

Flux Composition and Polarity

The last number, combined with the position designator, indicates the type of flux coating the electrode has, which in turn determines which polarity or polarities the electrode can be used with (see image 8.20 above).

Table 8.3. Flux Coating and Polarity

Last Digit

Type of Flux Coating

Type of Current

EXXX0

High cellulose sodium

DCEP

EXXX1

High cellulose potassium

AC, DCEP, DCEN

EXXX2

High titania sodium

AC, DCEN

EXXX3

High titania potassium

AC, DCEP, DCEN

EXXX4

Iron powder, titania

AC, DCEP, DCEN

EXXX5

Low-hydrogen sodium

DCEP

EXXX6

Low-hydrogen potassium

AC, DCEP

EXXX7

High iron oxide, iron powder

AC, DCEP, DCEN

EXXX8

Low-hydrogen potassium, iron powder

AC, DCEP, DCEN

EXXX9

Iron oxide titania potassium

AC, DCEP, DCEN

As previously stated, the flux coating is a very important part of the welding process for SMAW. During welding, it provides shielding for the weld in the form of a shielding gas and a coating of slag. It also provides alloying elements, deoxidizers, fluxing agents, and arc stabilizers. Additionally, the makeup of the flux determines the polarity required for each specific electrode and affects the arc’s electrical characteristics.

While all of these elements are true of each type of flux, they are all achieved in different proportions through different mixtures of flux components. The flux is a powder made up of a mixture of different metals and minerals that is baked onto the electrodes. The numbers 0-8, in combination with the position designator, indicate the type of flux mixture used (refer to Table 8.3 Flux Coating and Polarity). Each different flux mixture produces different welding characteristics for each type of electrode.

A 6010 fillet weld bead.
Figure 8.20. E6010 / Photo Credit: David Ridge, CC BY 4.0

For example, E6010 has a cellulose-based flux. This flux makes a violent digging arc that achieves greater weld penetration than other fluxes and leaves a small weld with a rough surface texture and a light coating of slag. It also causes the weld to solidify quickly (you may hear the term “fast freeze” used for this electrode) and allows this electrode to be less affected by surface contamination, such as oxides (rust) or moisture. In fact, E6010 is the electrode used for underwater welding. Today’s primary use for E6010 in industry is tacking and making the root pass on multi-pass welds.

A 6013 fillet weld bead.
Figure 8.21. E6013 / Photo Credit: David Ridge, CC BY 4.0

In contrast, E6013 has a titania based flux, which gives it a soft arc with little penetration. The weld tends to be wide and smooth and has a heavy slag cover. These electrodes are more susceptible to contamination on the base metal surface, requiring more cleaning to be done before welding. E6013 was designed for use on sheet metal and light-duty steel parts.

A 7018 fillet weld bead.
Figure 8.22. E7018 / Photo Credit: David Ridge, CC BY 4.0

E7018 is the workhorse of the stick welding industry. The potassium/iron powder flux creates a soft arc with moderate weld penetration. The weld produced is wide and smooth with a heavy slag cover and high strength and ductility properties. Therefore, these electrodes are highly susceptible to contamination, especially from hydrogen (the primary element in water), and are called “low-hydrogen” electrodes. The electrodes must be kept in a special rod oven to keep hydrogen from the moisture in the air from saturating the flux. Proper cleaning and weld zone preparation are also necessary before welding. Industrial steel fabrication and construction requiring stick welding are often welded with E7018.

Once again, the polarity for each electrode is determined by the chemistry of the flux. For example, E6010 has a cellulose/sodium flux and can only be run on DCEP. Because of certain equipment needs, welders wanted to be able to run E6010 on AC. By changing the flux to a cellulose/potassium mixture, the manufacturers created E6011, which is essentially the same electrode as E6010 but has the capability to run on AC or DCEP. E6013’s titania/potassium flux allows it to be run on AC, DCEP, or DCEN.

With all that being said, it is less important that you memorize the characteristics of each individual electrode based on the flux number than for you to know where to look the information up. Every type of electrode has product information that can easily be obtained from the manufacturer for free. This information should give you the polarity and amperage requirements for each electrode and some indications of the techniques used in welding with them. If this information cannot be located, be sure to ask your instructor or welding supervisor for help. Learning how to run each electrode correctly is a matter of experience. In industry, unless you are running your own welding business, the type of electrode to be used on any job will be determined by the project engineer. You will not be responsible for electrode selection. Your responsibility is to know how to weld with that electrode.

A piece of plate with three weld beads made with different electrodes. Each of the beads is labeled.
Figure 8.23. Weld Beads Made By Different Electrodes / Photo Credit: David Ridge, CC BY 4.0

Suffix/Additional Requirements Met

In some cases, you may see the primary electrode classification followed by several other letters and numbers. This is the suffix and/or the additional welding requirements met by this electrode.

A diagram of an electrode classification including the suffix and additional requirements. Each part is labeled. The parts are discussed in the text below the image.
Figure 8.24. Suffix and Additional Requirements / Photo Credit: © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator)

The suffix will be a combination of one letter and one number, such as A1 or C3. The suffix tells you the approximate alloying composition of the finished weld. If there are letters or numbers other than the suffix, these indicate certain welding requirements this specific type of electrode meets. For example, H4 indicates that the finished weld will contain no more than four parts per million of diffused hydrogen. This is often seen on E7018 rods, as these are low-hydrogen electrodes.

While this additional information can be helpful in the right circumstances, it is not critical for you to memorize.

Attributions

  1. Figure 8.16: Types of welding electrode by Ghasemimoshref is released under CC BY-SA 4.0
  2. Figure 8.17: SMAW Electrode Classification © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator) Used with permission from the rightsholder, the American Welding Society.
  3. Figure 8.18: Example of SMAW Electrode Classification © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator) Used with permission from the rightsholder, the American Welding Society.
  4. Figure 8.19: SMAW AC Setup by Nicholas Malara, for WA Open ProfTech, © SBCTC, CC BY 4.0
  5. Figure 8.20: E6010 by David Ridge, for WA Open ProfTech, © SBCTC, CC BY 4.0
  6. Figure 8.21: E6013 by David Ridge, for WA Open ProfTech, © SBCTC, CC BY 4.0
  7. Figure 8.22: E7018 by David Ridge, for WA Open ProfTech, © SBCTC, CC BY 4.0
  8. Figure 8.23: Weld Beads Made By Different Electrodes by David Ridge, for WA Open ProfTech, © SBCTC, CC BY 4.0
  9. Figure 8.24: Suffix and Additional Requirements © American Welding Society, illustration by Nicholas Malara (SBCTC Illustrator) Used with permission from the rightsholder, the American Welding Society.
definition

License

Icon for the Creative Commons Attribution 4.0 International License

Introduction to Welding Copyright © by David Ridge is licensed under a Creative Commons Attribution 4.0 International License, except where otherwise noted.